Nissanhelp.com - All About Nissan
Bookmark and Share

Nissan > Engine Codes > P1276
Models: Most Nissan Models

DTC: P1276

Search Bulletins/Recalls for P1276

Trouble diagnosis name: Air fuel ratio (A/F) sensor 1 (Bank 1) circuit high voltage

Component Description

The A/F sensor is a planar dual-cell limit current sensor. The sensor element of the A/F sensor is the combination of a Nernst concentration cell (sensor cell) with an oxygen-pump cell, which transports ions. It has a heater in the element.

The sensor is capable of precise measurement λ= 1, but also in the lean and rich range. Together with its control electronics, the sensor outputs a clear, continuous signal throughout a wide λ range (0.7 < λ < air).

The exhaust gas components diffuse through the diffusion gap at the electrode of the oxygen pump and Nernst concentration cell, where they are brought to thermodynamic balance.

An electronic circuit controls the pump current through the oxygen-pump cell so that the composition of the exhaust gas in the diffusion gap remains constant at λ = 1. Therefore, the A/F sensor is able to indicate air/fuel ratio by this pumping of current. In addition, a heater is integrated in the sensor to ensure the required operating temperature of 700 - 800°C (1,292 - 1,472°F).

DTC detecting condition:

  • The A/F signal computed by ECM from the A/F sensor 1 (Bank 1) signal is constantly approx. 1.5V.

Possible cause:

  • Harness or connectors (The A/F sensor 1 circuit is open or shorted.)
  • Air fuel ratio (A/F) sensor 1

 

THINGS YOU CAN DO ALSO ON NISSANHELP.COM NISSANHELP.COM STORE